Specification |
Temperature | Resistance (kx) | |
°C | °F | |
-40 | -40 | 48.14 |
-20 | -4 | 14.13 ~ 16.83 |
0 | 32 | 5.79 |
20 | 68 | 2.31 ~ 2.59 |
40 | 104 | 1.15 |
60 | 140 | 0.59 |
80 | 176 | 0.32 |
Hyundai Tucson (LM) 2010-2015 Service Manual: Luggage Room Lamp Repair procedures
Removal
1.
Disconnect the negative (-) battery terminal.
2.
Remove the luggage room lamp (B) when prying the hole (A) with a flat-up screwdriver
3.
Remove the luggage room lamp bulb in case of necessity
Installation
1.
Replace the lamp bulb.
2.
Install the luggage room lamp asse ...
Hyundai Tucson (LM) 2010-2015 Service Manual: Ambient Sensor Description and Operation
Description
1.
The ambient temperature sensor is located at the front of the
condenser and detects ambient air temperature. It is a negative type
thermistor; resistance will increase with lower temperature, and
decrease with higher temperatures.
2.