Hyundai Tucson: Air Conditioning System / Ambient Sensor Description and Operation

Description
1.
The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperatures.
2.
The sensor output will be used for discharge temperature control, temperature regulation door control, blower motor level control, mix mode control and in-car humidity control.
   
If the ambient temperature is below 2.0°C (35.6°F), the A/C compressor will be stopped.
The compressor will be operated by manual operating.
Photo Sensor Repair procedures
Inspection 1. Ignition "ON" 2. Using the scan tool. 3. Emit intensive light toward photo sensor using a lamp, and check the output voltage change. 4. The voltage will rise with higher ...

Ambient Sensor Repair procedures
Inspection 1. Ignition "OFF" 2. Disconnect ambient temperature sensor. 3. Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing o ...

Other information:

Hyundai Tucson (LM) 2010-2015 Service Manual: TPMS Receiver Description and Operation
Description 1. Mode (1) Virgin State A. The receiver as a sole part is shipped in this state. Replacement parts should therefore arrive in this state. B. In this state, there is no sensor monitoring and no DTC monitoring. C. The state indicates that platform specific parameters must ...

Hyundai Tucson (LM) 2010-2015 Service Manual: Repair procedures
On-vehicle Inspection Inspect ignition coil assembly and Perform spark test 1. Check for DTCs.     • If a DTC is present, perform troubleshooting in accordance with the procedure for that DTC. (Refer to DTC guide) 2. Check if sparks occur. (1) Remove the engi ...